Combustion Blower
High-pressure centrifugal fans use high-speed rotating impellers to generate centrifugal force, accelerating the gas and converting it into pressure energy to produce a high-pressure airflow. These fans typically feature forward-curved or backward-curved blade designs, characterized by high rotational speeds and high static pressure, and are capable of meeting the demands of forced ventilation, material conveying, and high-temperature flue gas treatment.
Request a Quote
Enter the quantity you need and add to your quote list for pricing inquiries.
Description
| Machine | Model number | Auxiliary motor(KW-P) | Rotational speed (r/min) | Flow rate(m³/h) | Total pressure(Pa) | Voltage(V) |
|---|---|---|---|---|---|---|
| 3.15A | Y80M-2 | 0.75-2 | 2900 | 390-610 | 1919-1953 | 380 |
| Y801-2 | 1.1-2 | 2900 | 700-810 | 1926-1755 | 380 | |
| 3.55A | Y90S-2 | 1.5-2 | 2900 | 860-760 | 2554-2590 | 380 |
| Y90L-2 | 2.2-2 | 2900 | 560-1160 | 2545-2310 | 380 | |
| 4.OA | Y90L-2 | 2.2-2 | 2900 | 824-1264 | 3584-3597 | 380 |
| Y100L-2 | 3-2 | 2900 | 1410-1704 | 3507-3253 | 380 | |
| 4.5A | Y112M-2 | 4-2 | 2900 | 1174-2062 | 4603-4447 | 380 |
| Y132S1-2 | 5.5-2 | 2900 | 2281-2504 | 4297-4112 | 380 | |
| 5A | Y132S2-2 | 7.5-2 | 2900 | 1610-2844 | 5697-5517 | 380 |
| Y160M1-2 | 11-2 | 2900 | 3166-3488 | 5323-5080 | 380 | |
| 5.6A | Y160M1-2 | 11-2 | 2900 | 2262-3619 | 7182-7109 | 380 |
| Y160L-2 | 18.5-2 | 2900 | 3996-4901 | 6954-6400 | 380 | |
| 6.3A | Y160L1-2 | 18.5-2 | 2900 | 3220-5153 | 9149-9055 | 380 |
| Y180M-2 | 22-2 | 2900 | 4509-5690 | 9219-8857 | 380 | |
| Y200-L1-2 | 30-2 | 2900 | 5690-6978 | 8857-8148 | 380 |
Typical Application Scenarios
Industrial Forced Ventilation: Suitable for forging furnaces, boiler draft systems, blast furnace air supply, and chemical reactor gas supply, overcoming the resistance of furnace chambers and complex piping systems.
Material Conveying: Used for long-distance pneumatic conveying of powdery or granular materials such as cement, fly ash, grain, and plastic pellets.
Environmental Protection and Dust Removal: Equipped with reverse-pulse cleaning systems for bag filters or electrostatic precipitators, as well as industrial waste gas treatment and emission processes.
Special Environment Treatment: Suitable for forced exhaust or high-pressure discharge in industries such as spraying, electroplating, glass manufacturing, and battery production.
Key Features
High Pressure and High Efficiency: Total pressure can reach 3000~25000 Pa, and the total pressure efficiency of some high-efficiency models can reach 82%~85%, significantly reducing operational energy consumption.
Robust and Durable Structure: The casing is continuously welded from thick steel plates, and the impeller undergoes static and dynamic balancing correction, ensuring smooth operation and vibration resistance.
Material and Process Adaptability: For high-temperature or corrosive gases, special materials such as heat-resistant alloys, stainless steel, or titanium plate welding can be selected to extend equipment lifespan.
Flexible Transmission and Installation: Supports direct motor drive (Type A) or coupling transmission (Type D); the outlet angle can be rotated and adjusted (0° to 225°) according to on-site requirements.
FAQ
What are the requirements for the medium being transported by the high-pressure centrifugal fan?
The medium usually needs to be non-corrosive, non-flammable and non-explosive, free of viscous substances, and the dust and hard particles contained should not exceed 150mg/m³. The medium temperature is generally no more than 50℃ (with a maximum of no more than 80℃). Special high-temperature models can be customized with temperature-resistant design.
When the fan operates, it shows severe vibration or abnormal noise. What could be the possible causes?
Common causes include damage to the dynamic balance due to accumulated dust on the impeller, wear of the bearings, loosening of the foundation bolts, or excessive stress on the piping. It is recommended to stop the machine, clean the impeller, inspect and tighten the bolts, and in case of necessity, perform dynamic balance correction or replace the bearings.
How can one determine if there is a malfunction where the fan's air volume or air pressure is insufficient?
First, check whether the air intake filter is clogged, whether the pipeline is leaking, and whether the gap between the impeller seals is too large. If the air volume decreases significantly, the performance can be restored by cleaning the filter, sealing the pipeline leaks, or replacing the seals.